ET-8352F – heating area >20m²

Open Area Control System

  • Controls two separate heating zones
  • Gutter or free-fall sensor or a combination of both
  • Monitors temperature and humidity
  • Reliable and secure

Note: ET-8352F Control also available with sensor housing (Product code: ET-8352F-BE)

Category:

Description

Fully automatic temperature control of open space heating systems for installation in distribution board cabinet on normal DIN rails, LCD display of current values: Temperature, humidity, Operation; Fault status, running time counter; Re-heat function adjustable, alarm output for sensor malfunction, relay output 16 A.

Application

Use with open area heating mats for stairways, ramps and roads.

Specification

  • Voltage: 230 V, 50/60 Hz
  • Relay output: 16 A
  • Mounting: On standard DIN rail
  • Dimensions: 106 x 90 x 59 mm
  • Sensor intervals: every 15 m
  • Re-heating function
  • Alarm signal for sensor error status
  • Approval: CE compliant

Installation

Sensor Positioning

  1. Ice- and Snow Sensor
    On a unheated part of the surface to determine humidity and temperature
  2. Temperature Sensor
    Positioning on Weather side to determine exterior temperature